PTFE Chemical Resistance Data Chart | Component Supply

PTFE Chemical Resistance Chart. PTFE extruded tubing, and PTFE shrink tubing, are used by our customers in various industries and in different appliions, which may require resistance to specific chemicals. While this chart is a useful reference, please note that it is the end users'' responsibilities to evaluate and test the fitness of the product for their specific appliions.

POLYVINYL CHLORIDE (PVC) CHEMICAL RESISTANCE DATA - …

30/5/2019· CHEMICAL RESISTANCE DATA R – Generally Resistant C – Less resistant than R but still suitable for some conditions N – Not resistant Hydrochloric acid R R Maleic acid R R Hydrofluoric acid, 10% R C Malic acid R R Hydrofluoric acid, 60% R C Manganese sulfate R R Source: PPI TR-19 Plastic Pipe Institute, New York, New York .

Corrosion | Chemical Processing Expert Forum: Re: What

1/1/2013· In general, nonmetalic materials have better resistance to hydrochloric acid than metallic materials. Rubber-lined vessels are commonly used for hydrochloric acid storage. Polypropylene, PVC, PTFE, FEP, PFA, ECTFE, PVDF, and FRP can be used as long as long as recommended temperature limits are followed.

Guide to Impact of Chemicals on EPDM Rubber

Guide to Impact of Chemicals on EPDM Rubber. This guide will help in assessing the impact different chemicals may have on EPDM rubber. This data has been compiled by other reputable sources and is to be used solely as a guide in selecting EPDM or determining it''s durability and resistance to chemical exposure.

Hydrochloric Acid - Rolled Alloys, Inc.

Hydrochloric acid (HCl) is a clear colorless liquid that is highly corrosive, and considered a strong mineral acid. The main appliions of HCl are for pickling steel, acid treatment for oil wells, chemical cleaning, and chemical processing for large scale production of vinyl chloride. It is produced in several concentrations with the max

hydrochloric acid resistant hose in the philippines

Hydrochloric acid on the other hand is not recommended and will damage all stainless steel. Generally speaking, type 316 is considered more resistant to solutions of chlorides, bromides, iodides and fatty acids at high temperatures while most oxidising acids such as nitric acid and phosphoric acid can be used with type 304 at room temperature.

Chemical Resistance Chart - Rubber Chemical Resistance

Rubber Chemical Resistance. This tool can be used to view the resistance of thousands of chemicals with different rubbers such as Viton and Nitrile. EPDM is extremely resistant to many chemicals such as Acetaldehyde, Acetamide, and Ammonia. Viton is resistant to many hydrocarbons and is best to use with chemicals in the petroleum industry.

Corrosion Protection - REMA TIP TOP

Chemically resistant against: Mineral acids, bases, aqueous phases and in particular concentrated hydrochloric acid up to 60°C-80°C. Continuous use temperature: 80°C Appliions / Miscellaneous: Widely used in electroplating and particularly where hydrochloric acid is contacted (HCI storage tanks).

Corrosion Resistant Rubber Liners: What to Consider for

24/5/2018· Soft rubber’s corrosion resistant properties can withstand many abrasive materials. It is commonly used for hydrochloric acid appliions. However, this type is not suited to handle any strong oxidizing agents. Semihard natural is very similar to soft natural rubber, but firmer. This characteristic makes it more durable and chemical resistant, enabling semihard natural …

Chemical Resistance, SBR, EPDM, NBR

The table below is a guidance of the chemical resistance of rubber materials. This is only a recommendation, which gives no obligation or warranty on account of Trelleborg Pipe Seals B.V. CHEMICAL RESISTANCE Concentration % Grade 1 = No significant effect Hydrochloric acid 10 100 3 4 3 Hydrochloric acid 21 50 2 2 2

Rubber Chemical Compatibility Chart & Resistance Guide

Minor Rubber''s extensive compatibility chart will assist in the design and selection of your manufactured rubber product. View now!

uPVC Chemical Resistance Chart - Marley

by selecting a higher SN rating pipe. Class 3: NO RESISTANCE - all material belonging to this class are subject to corrosion by the conveyed fluid and they should therefore not be used. The absence of any class indiion means that no data are available concerning the chemical resistance of the material in respect of the conveyed fluid.

Chemical Resistance Chart for HDPE (High Density Polyethylene)

Chemical Resistance Chart for HDPE (High Density Polyethylene) The chemical resistance chart below is a general guide only. Please contact MENDA for specific appliions. Acetaldehyde - GF Diethyl Benzene - FN Methyl Ethyl Ketone - NN Carbon Disulfide - NN Hydrochloric Acid, 5% - EE Sulphuric Acid, 20% - EE

Chemical Resistance of PVC Pipes - Vinidex Pty Ltd

medical˜appliions, pipe systems and˜many others. PP chemical resistance HMC Polymers’ polypropylene resins, like most polyole˚ns, are highly resistant to solvents and chemicals. The results of extensive laboratory and actual ˚eld installation tests of polypropylene’s chemical resistance are reported in this

Master Bond Acid Resistant Polymer Systems | MasterBond

Serviceable from +400°F. Exceptional acid resistance. Cures at room temperature. Good flow properties. 100% reactive. Low shrinkage upon cure. Withstands 1,000 hours 85°C/85% RH. Reliable electrical insulator. Adheres well to metals, glass, ceramics, rubbers and plastics. Shore D hardness 80-90.

Hydrochloric Acid Hose | McMaster-Carr

Choose from our selection of hydrochloric acid hose, including over 475 products in a wide range of styles and sizes. In stock and ready to ship. About Plastic and Rubber Tubing. More. Chemical Hose. Low-Pressure Chemical Hose. An FEP liner gives this tubing better chemical resistance than any of our other soft tubing.

Corrosion tables — Materials Technology

The corrosion data in this section is mainly based on the results of general corrosion laboratory tests, which are not strictly comparable with actual service conditions.The corrosion tables provide an initial guide to the selection of materials and are intended to facilitate understanding of the different types of corrosion damage that can arise due to poor material selection.

CHEMICAL RESISTANCE GUIDE - Primary Fluid

Outstanding resistance to chemical attack by most chemicals and solvents. It is a self-lubriing compound and has a temperature rating of 20ºF - 400ºF [--29ºC - 204ºC]. [ marine atmosphere and exhibits exceptional resistance to a . ELASTOMER. VITON® [Fluorocarbon Rubber abv. FPM]

Rubber Chemical Resistance Chart, Rubber Compatibility

Use this rubber chemical resistance chart to make sure that the elastomer or O-ring seal you choose will be compatible with the particular environment. The chemical compatibility of rubber is extremely important as the rubber can degrade rapidly if the rubber material is not compatible with the environment or media that it comes into contact with.

Gasket Selection Guide B-03

Chemical Resistance B-03 GENERAL GASKET SERVICE RECOMMENDATIONS The following are general service recommendations only and the information provided is based on the best information available from various resources including elastomer manufacturers, leading rubber molders, industry publiions and our own laboratory testing and field experience.

Rubber Hose Chemical Resistance Chart - NovaFlex Group

Rubber Chemical Resistance Chart page 2 Chemical Temp ºF Natural Rubber (NR) SBR Butyl (IIR) EPDM Neoprene (CR) Hypalon (CSM) Nitrile (NBR) Crosslinked Polyethylene (XLPE) Flurocarbon (Viton/Fluorel) Flurocarbon Plastic (Teflon/TFE/FEP) Modified Cross-link UHMWP Tube Compounds Air 200 F 70 X C E E G C G X E E E E Air, Aeint 70 E E E E E E E

Acrylic Chemical Compatibility Chart | TDI International, Inc.

Hydrogen Peroxide, 28%. Limited Resistance (Short Time Compatibility) Iodine. Resistant (Compatible) Isopropyl Alcohol, to 50%. Limited Resistance (Short Time Compatibility) Lactic Acid, to 80%. Limited Resistance (Short Time Compatibility) Magnesium Chloride.

Corrosion Resistance Chart - Dixon Valve US

3. Chemical resistance of a material does not necessarily indie the suitability of a fitting in a given appliion due to variables such as improper clamp and coupling appliion, special hose construction, gasket material, etc. 4. Special caution should be taken when handling hazardous materials. Corrosion Resistance Chart

hydrochloric acid resistant hose price philippines

Hydrochloric Acid, chemically written as HCl, is a common compound that is very useful for a wide-range of appliions. The same compound that actively works to break down the food that people digest, it is also used in making every day products like batteries, fertilizers, in addition to the production of other materials that we use daily.

Polyethylene pipe (PE & HDPE) : Properties and Types of

Rapid crack propagation resistance. HDPE PE100 pipe is easy to install, light, flexible, corrosion-free and has a service life of up to 100 years. It can be jointed using butt fusion or electrofusion to create a leak-free pressure network for gas or water. For the trenchless appliions butt fusion is most widely used because this results in a

Chemical Resistance Chart Acetaldehyde - Alcohols (Propyl)

Chemical Resistance Chart Acetaldehyde - Alcohols (Propyl) Chemical Resistance Data These recommendations are based upon information from material suppliers and careful examination of available published information and are believed to be accurate. However, since the resistance of metals, plastics and elastomers